Care and Maintenance
It is important to wipe the caliper with a lint-free cloth after
exposure to moisture. Apply a very light coat of lubricant
on all the mechanical parts. Do not use aggressive sol-
vents to clean the plastic components. Do not store the
instrument in areas of extreme temperature.
SPECIFICATIONS
Dust/ Water Protection:
IP67 according to IEC529
• The first number “6” identifies protection against
complete ingress of dust.
• The second number “7” identifies protection against
the ingress of water when submerged 1 meter deep for
30 minutes.
Ranges:
0-6"/0-150mm
0-8"/0-200mm
0-12"/0-300mm
Resolution:
0.0005"/0.01mm
*Accuracy:
±0.001"/0.02mm
(≤4"/100mm)
±0.001"/0.03mm
(>4"/100mm)
* Meets the accuracy
requirements of DIN 862
Auto Shutdown:
30 minutes of non-use
Operational Temp.:
+41º-104ºF(+5º-+40ºC)
Data Output
(798B only): Patented
non-contact USB cable
Battery:
Lithium Coin Cell 3V -
CR2032 or Equivalent
Battery Life:
>3500 hours continuous
use